Diagnose a Well Pump That Won't Build Pressure
Category: Mechanical ·
Difficulty: Intermediate ·
Time: 1.5h ·
Estimated cost: $45
Tools needed
- Multimeter
- Tire pressure gauge
- Adjustable wrench
- Screwdriver set
- Flashlight
Materials needed
- Pressure switch (30/50 or match existing) (1 ea)
- Pressure gauge (0-100 psi, spare) (1 ea)
- PTFE thread tape (1 roll)
Execution steps
Kill power and read the gauge
Shut off the pump breaker. Read the pressure gauge — note where the needle sits. This is your baseline before touching anything.
Duration: 5 min
Check the pressure tank
With the system drained to zero, check the tank's air charge with a tire gauge at the Schrader valve. It should read 2 psi BELOW your cut-in pressure (28 psi for a 30/50 switch). A waterlogged tank is the most common cause of short-cycling.
Duration: 15 min
Inspect the pressure switch
Pull the switch cover. Look for burned contacts, ant nests, or corrosion — ants love pressure switches and kill more of them than wear does. Clean contacts gently or replace the switch.
Duration: 15 min
Test for power
Breaker back on, multimeter on the switch terminals: you should read line voltage in and (when pressure is below cut-in) voltage out to the pump. Power in but nothing out with low pressure = dead switch.
Duration: 15 min
Replace the switch if dead
Power OFF again. Swap wires one at a time to the new switch so nothing gets crossed. PTFE tape the nipple threads. Set cut-in/cut-out per the label (usually 30/50).
Duration: 25 min
Recharge and test
Restore power. Watch the gauge climb to cut-out and the pump shut off. Run a tap — the pump should kick on at cut-in. Short-cycling after this means the tank bladder is shot.
Duration: 15 min
Safety first
- GOOD — Diagnose in order: tank charge, then switch, then pump. Most 'dead pump' calls are a $25 switch or a waterlogged tank.
- GOOD — Move wires one at a time when swapping the switch. A crossed wire on 240 volts is not a learning experience you want.
- BAD — Ignore short-cycling and the pump will burn itself out from starting every 30 seconds. A $200 tank now beats a $1,500 pump later.
- HOLY SHIT — Well pumps run on 240 volts, often with no disconnect at the wellhead. Test every wire with the meter before your hands go in — 'I thought the breaker was off' is what the report says afterward. Lock the breaker if you can.
When to hire a pro
If the pump runs but builds no pressure (bad pump or dropped pipe down the well), if the well runs dry, or if there's any sign of electrical burning at the panel — that's a well driller or electrician, not DIY.